Current environment: staging

65232213 Kitchen faucet, 230/5 V

HANSA FIT Hybrid

Active markets
Find a retailer

EAN: 4015474273443

Documents

DatasheetProduct description

Technical information and properties

Features

Additional features

Faucet is GGT-approved user test VERY GOOD

Aerator type

Hidden aerator

Connection

Flexible inlet pipes

Electronic parts

Autofocus infrared sensor, Solenoid valve, External control unit, Power supply, Light indicated function(s)

Lever/Handle

Two operating levers/handles, Easy-Grip surface

Mechanical parts

Ceramic head part for flow control, Mixing valve for manual temperature control, Litter filter(s)

Mounting holes

1 hole

Advanced features

Surfaces in contact with drinking water contain less than 0.3% lead, Inner body made of DZR brass, Waterways without nickel coating, Software settings adjustable via buttons

Spout

Swivel spout, Swivel range limiting option

Color

Chrome

Software settings

Afterflow period

4 s (2/4/8/10/20 s)

Automatic flush

off (off/12/24/48/72 h)

Automatic flush period

30 s (10/30/60/120/180 s)

Max. flow period

40 s (10/40/60/120/180 s)

Flow attributes

Flow-rate at 3 bar

0.2 l/s (12 l/min)

Pressure loss with flow (12 l/min)

2.9 bar

Technical properties

Backflow prevention (EN1717)

AA

Connection size

G3/8

DN-size (nominal dimension)

DN15

Hot water supply

max. +70°C

Material

Brass/Composite

Projection

193 mm

Working pressure

1 - 10 bar

Electronics

Electrical Connection

230 / 5 V

Regulations

EMC Directive

Low Voltage Directive 2014/35/EU , EMC Directive 2014/30/EU , RoHS Directive 2011/65/EU

EN standard

ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4

Noise class

I (ISO 3822)

Protection class

IP 54 / transformer IP 20

Sustainability

EPD module A1 (kg CO2 eq.)

16,21

EPD module A1-A3 (kg CO2 eq.)

26,52

EPD module A2 (kg CO2 eq.)

0,75

EPD module A3 (kg CO2 eq.)

9,53

EPD module A4 (kg CO2 eq.)

0,71

EPD module B7 (kg CO2 eq.)

2364,00

EPD module C2 (kg CO2 eq.)

0,03

EPD module C3 (kg CO2 eq.)

0,04

EPD module C4 (kg CO2 eq.)

0,68

EPD module D (kg CO2 eq.)

-12,86

User Test

Covered by HANSA's guarantee